 | metal-ceramic tube
|  |
CERMET X-RAY TUBES, PRODUCED BY THALES ELECTRON DEVICES (FRANCE)
for the industrial radiography and radioscopy

|
High-reliable cermet X-ray tubes, designed for the voltage range from 100 kV to 450 kV for stationary units of cable type EXTRAVOLT series. Tubes are designed for the industrial use when inspecting plastics, ceramics, composites, welded connections, light-alloy and steel castings, products made of high-temperature alloys and for the analysis of internal structure of the products. |

|
Cermet tubes |
|
Tube designation
|
Maximum parameters
|
Size of focal spot
|
Target angle
|
Emergent beam angle
|
Cooling
|
Weight
|
PDF
|
|
Voltage kV
|
Power capacity W
|
mm
|
°
|
kg
|
|
One-pole X-ray tubes with earthed, water cooled anode
|
|
THX 100/1055
|
100
|
900 3000
|
0 .4 3.0
|
21
|
40
|
water
|
6.5
|

|
|
THX 100/1030
|
100
|
900 2500
|
0.4 1.5
|
21
|
40
|
water
|
6.5
|

|
|
THX 100/0510
|
100
|
450 900
|
0.2 0.4
|
21
|
40
|
water
|
6.5
|

|
|
|
|
|
THX 160/G
|
160
|
4000
|
3 .0x4.0
|
30
|
40
|
water
|
6.5
|

|
|
THX 160/1055
|
160
|
900 4000
|
0.4 3.0
|
21
|
40
|
water
|
6.5
|

|
|
THX 160/1030
|
160
|
900 2500
|
0.4 1.5
|
21
|
40
|
water
|
6.5
|

|
|
THX 160/0510
|
160
|
450 900
|
0.2 0.4
|
21
|
40
|
water
|
6.5
|

|
|
THX 1060/1010
|
160
|
900 900
|
0.4 0.4
|
21
|
40
|
water
|
6,5
|

|
|
|
|
|
THX 180
|
180
|
2700
|
1 .5
|
21
|
85 x 14
|
water
|
21*
|

|
|
|
|
|
THX 225/WA
|
225
|
4000
|
3.0
|
21
|
90 x 15
|
water
|
12
|

|
|
THX 225/G
|
225
|
4000
|
3.0x4.0
|
30
|
40
|
water
|

|
|
THX 225/1055
|
225
|
900 4000
|
0.4 3.0
|
21
|
40
|
water
|
12
|

|
|
THX 225/1030
|
225
|
900 2500
|
0.4 1.5
|
21
|
40
|
water
|
12
|

|
|
THX 225/0510
|
225
|
450 900
|
0.2 0.4
|
21
|
40
|
water
|
12
|

|
|
One-pole X-ray tubes with earthed, air cooled anode
|
|
|
MBE 161 / 5
|
160
|
640 1000
|
0.5 1.5
|
21
|
50 x 45
|
air
|
2.1
|

|
|
MBE 200
|
200
|
900
|
1.5
|
21
|
40
|
air
|
2.3
|

|
|
MBE 250
|
225
|
900
|
1.5
|
21
|
40
|
air
|
2.6
|

|
|
Two-polar X-ray tubes with earthed center, being cooled with high-voltage oil
|
|
|
MB 320 / 3 H320C
|
320
|
900 2250
|
0.8 1.8
|
10
|
30
|
oil
|
41
|

|
|
|
|
|
MB 350 / 1 H450C
|
350
|
1500 4200
|
1.5 3.5
|
21
|
40
|
oil
|
97
|

|
|
MB 350 / 3 H350C
|
350
|
900 2250
|
0.8 1.8
|
10
|
30
|
oil
|
45
|

|
|
MB 350 / 5 H350C
|
350
|
640 1500
|
0.2 0.4
|
10
|
30
|
oil
|
45
|

|
|
|
|
|
MB 380 / 3 H380C
|
380
|
900 2250
|
0.8 1.8
|
10
|
30
|
oil
|
54
|

|
|
|
|
|
MB 420 / 1 H450C
|
420
|
1500 4200
|
1.5 3.5
|
21
|
40
|
oil
|
97
|

|
|
MB 420 / 3 H450C
|
420
|
900 2250
|
0.8 1.8
|
10
|
30
|
oil
|
97
|

|
|
MB 420 / 5 H450C
|
420
|
640 1500
|
0.2 0.4
|
10
|
30
|
oil
|
97
|

|
|
|
|
|
MB 450 / 1 H450C
|
450
|
1500 4500
|
1.5 3.5
|
21
|
40
|
oil
|
97
|

|
|
MB 450 / 3 H450C
|
450
|
900 2250
|
0.8 1.8
|
10
|
30
|
oil
|
97
|

|
|
MB 450 / 5 H450C
|
450
|
640 1500
|
0.2 0.4
|
10
|
30
|
oil
|
97
|

|
|
|
|
|
MBWA 450 / 1 H450 WAB
|
450
|
1500 3500
|
1.5 3.3
|
21
|
105 x 10
|
oil
|
97
|
|
|
MBWA 420 / 1 H450 WAB
|
420
|
1500 3500
|
1.5 3.3
|
21
|
105 x 10
|
oil
|
97
|
|
* including cable
Any one-pole tubes can operate with any one-pole units of EXTRAVOLT series, as well as any two-polar tubes can operate with any two-polar generators. When the maximum modes of the tube and generator don’t coincide the real modes shall be restricted to that component which modes are lower.
For example, the unit EXTRAVOLT-225 can operate with the tube designed for 160kV, its maximum voltage being 160kV instead of 225kV. The unit EXTRAVOLT-160 can operate with the tube designed for 225kV, its maximum voltage being 160kV.
Such compatibility is often used by clients to save money. For example, the client who, at given moment, needs the unit EXTRAVOLT-160, often purchases the unit EXTRAVOLT-225, completed with the tube designed for 160kV. If in the future the client would need the higher voltage, it would be enough for him to substitute only the tube with more high-voltage one without changing the whole unit. It also happens very often that clients who have to radiograph steels of big thickness, purchase the unit EXTRAVOLT-450 together with the tube designed for 350kV, meaning to substitute it in the future with the tube designed for 420kV or 450kV, if necessary.