MCT-160 – this fine-focus unit is designed, first of all, for cheap X-ray television systems and for the high-accuracy radiography of plastics, composites, ceramics, rubber, light-alloy castings and similar objects when the use of stationary cable unit is impossible or economically not substantiated.

It could be used for the radiographic inspection of pipelines welds in field conditions. The optimum thickness of the wall of pipe 700mm in diameter should not exceed 15mm. When using the FOSFOMATIC system or high-speed films type KODAK HS800 or intensifying screens it is possible to inspect pipelines with pipe walls of bigger thickness.

Technical characteristics:

Maximum voltage of the tube: 160 kV
Maximum anode current of the tube: 5 mA
Maximum power on the anode of the tube: 640 W
Depth of radiographic inspection in terms of steel: 40 mm*
Size of focal spot: 1.5 mm
Anode material: tungsten
Beam angle: 45ºx55º
Internal inherent filtration: 1 mm Be
High voltage adjustment range: 10...160 kV with pitch of 1 kV
Tube current adjustment range: 0.5...5 mA with pitch of 0.1 mA
Exposure time (pitch of 0,1 min): 0.1 ... 30 minutes or continuously
Weight of radiator: 16 kg together with lead shield
Weight of control unit: 7 kg
Design: waterproof
Tube burn-in: automatic
Quantity of preset programs: 255
Working cycle: 100% (Тaver.=20ºС)
Working range of temperatures:
-10ºС …+75ºС (standard design)
-40ºС …+75ºС (winter design)
Humidity: up to 90% without condensation
Cable length to the radiator: 20 m (standard), 100m (by request)
Voltage:
100V...250V   50/60Hz, generator,
storage battery by request
Storage conditions: -50ºС …90ºС,
Maximum power demand: 1.0 kW

* The radiographic inspection depth in terms of steel is given for following test conditions:
FOSFOMATIC-35, distance 700mm, 160kV, 640W, 1st class of sensitivity as per GOST 7512-82.
At the operation in the mode of high dose sensitivity the radiographic inspection of big-thickness steels is possible.

Nomographic chart for iron (Fe)
Distance to the object 700mm
Film class KODAK AA400, FOMA R7, AGFA D7
Lead shield 0,02 mm
Radiographic inspection until the achievement of density 2.0D.

Nomographic chart for iron (Fe)
Distance to the object 700мм
FOSFOMATIC-35 (Flex HR)
Lead shield 0,02 mm
Radiographic inspection as per 1st class of sensitivity in accordance with GOST 7512-82

Data could be changed without notification

References to the additional information:
Specification on MCT-160 in PDF
Sanitary and epidemiological conclusion on the unit МСТ-160
Description of the unit MCT-160
Criteria for selection of portable X-ray units

On the pictures:
Экспозиция мА х мин – Exposure mA x min
Радиационная толщина мм – Radiation thickness, mm


Rambler's Top100